Body | IssueThe BMP71 and M710 gives a "cover not closed" error, even though the cover is closed. Troubleshooting
- Open the cover and slowly and firmly close the cover. When the cover is closed, you will hear a "click".
- Inspect the printer for physical damage to the cover mechanism and sensor pins.
- Do not use 3rd party power supplies with this printer, only use the original power supply included with the printer.
- Power cycle the printer.
- If the error persists then the issue is likely mechanical failure of the sensor board. Contact Brady Technical Support for your region:
|
|
---|